Check longitudinal reinforcement
EuroCode - EN 1992-1-1 -
Author: Design Forms s.r.o.
Created: 7/25/2016
Last updated: 8/29/2016
Description:
Check of longitudinal reinforcement
Annotation:

Design compression and tension strength


(1)P Design concrete compression strength is defined by formula (3.15)



where γis partial factor of conctrete, see 2.4.2.4;


          αcc coefficient taking account of long term effects on the compressive strength


remark - αcc is defined by national annex, it maybe 0,8 - 1,0, recommended value is 1 (NP12)


(2)P Design concrete tension strenght is defined by formula (3.16)



where γc is partial factor of conctrete, see 2.4.2.4;

          αct coefficient taking account of long term effects on the tensile strength


remark - value αct is defined by national annex, recommended value is 1 (NP13)