Documentation

This document contains all National annex values, which are used in SDF - Basic package

Clause 4.2 Basic values, paragraph (1)P

Fundamental values of the basic wind velocity, vb,0 can be obtain from the table A.1 by selection place which is geographically closest to the construction site.
Table A.1 - Fundamental values of the basic wind velocity vb,0, basic velocity pressure qb,0 and altitude of the place in m.
Municipality Altitude Fundamental value of
basic wind velocity basic velocity pressure
vb,0 qb,0
m m/s kPa = kN/m2
Wien
Districts 10, 11, 21, 22 151 - 333 27,0 0,46
All other districts 151 - 542 25,1 0,39
Burgenland
Andau 118 25,1 0,39

Clause 4.2 Basic values, paragraph (2)P, NOTE 1

Altitude factor is taken into account in the values defined in table A.1
If the altitude of the construction site is more than 250 m above altitude of thr nearest municipality specified in the table A.1, basic values of the wind velocity and pressure should be obtained from the table A.2.
Table A.2 - Fundamental values of the basic wind velocity vb,0, basic velocity pressure qb,0 for sites more than 250 m above nearest municipality
Altitude
≤ 800 m 1800 m 3000 m
vb,0 in m/s 27,4 39,6 50,6
qb,0 in kN/m2 0,47 0,98 1,60
Note: Linear interpolation is used for values between defined altitude.

Clause 4.2 Basic values, paragraph (2)P, NOTE 2

Recommended value of the directional factor cdir = 1,0 for all wind directions.

Clause 4.2 Season factor cseason, paragraph (2)P, NOTE 3

Recommended value of the directional factor is cseason = 1,0

Clause 4.3.1 Variation with height, paragraph (1), NOTE 1

Recommended value of the orographic factor cO = 1

Clause 4.3.1 Variation with height, paragraph (1), NOTE 2

Calculations from Standard are not used. All wind parameters are given in dependancy on height of the construction and terrain category. They are in the table 1.
Table 1 - Profiles of the mean wind speed, turbulence intensity, the peak wind pressure and the gust wind velocity for three terrain categories
Terrain category II III IV
Minimal height zmin 5 m 10 m 15 m
Mean wind velocity vm for z > zmin 1,000 • vb • (z / 10)0,15 0,770 • vb • (z / 10)0,21 0,513 • vb • (z / 10)0,32
Mean wind velocity vm for zzmin 0,901 • vb 0,770 • vb 0,584 • vb
Turbulence intensity Iv for z > zmin 0,18 • (z / 10)-0,15 0,29 • (z / 10)-0,21 0,46 • (z / 10)-0,32
Turbulence intensity Iv for zzmin 0,18 0,29 0,46
Peak wind pressure qp for z > zmin 2,1 • qb • (z / 10)0,24 1,75 • qb • (z / 10)0,29 1,2 • qb • (z / 10)0,438/sup>
Peak wind pressure qp for zzmin 1,778 • qp 1,75 • qp 1,4 • qp
Gust wind velocity vp for z > zmin 1,449 • vb • (z / 10)0,120 1,323 • vb • (z / 10)0,145 1,095 • vb • (z / 10)0,190
Gust wind velocity vp for zzmin 1,333 • vp 1,323 • vp 1,183 • vp

Clause 4.3.2 Terrain roughness, paragraph (1)

Procedure from Standard is not used, because it is not necessary.

Clause 4.3.3 Orography, paragraph (1)

Recommended value of the orographic factor cO = 1

Clause 4.3.5 Closely spaced buildings and obstacles, paragraph (1)

Procedure from Standard is not used, because it is not necessary.

Clause 4.4 Wind turbulence, paragraph (1), NOTE 2

Formula from Standard is not valid.
Valid formulas are in table 1

Clause 4.5 Peak velocity pressure, paragraph (1), NOTE 1

Formula from Standard is not valid.
Valid formulas are in table 1

Clause 4.5 Peak velocity pressure, paragraph (1), NOTE 2

The recommended value of air density is ρ = 1,25 kg/m3

Clause 6.1 General, paragraph (1)

The construction coefficient cscd is usually not separated.

Clause 6.3.1 Structural factor cscd, paragraph (1), NOTE 3

The Procedure 1 stated in Annex B shall be used.

Clause 7.2.1 General, paragraph (1), NOTE 2

The recommended procedure given in Standard shall be used.

Clause 7.2.2 Vertical walls of rectangular plan buildings, paragraph (2), NOTE 2

Different table of coefficients for zones A, B, C, D, E is used.
Table 3 - External pressure coefficients cpe,10 for vertical walls of rectangular buildings in zones A, B, C
h/b A, B, C for d/b
≤ 0,2 0,7 1,0 2,0 5,0 ≥ 10
A B C A B C A B C A B C A B C A B C
≤ 0,5 -1,00 -0,70 -0,40 -1,00 -0,70 -0,40 -1,00 -0,70 -0,40 -1,00 -0,70 -0,40 -1,00 -0,70 -0,40 -1,00 -0,70 -0,40
2 -1,20 -0,80 - -1,20 -0,90 - -1,20 -0,80 -0,45 -1,10 -0,75 -0,40 -1,10 -0,70 -0,40 -1,10 -0,70 -0,40
5 -1,35 -1,00 - -1,45 -1,10 - -1,30 -0,90 -0,50 -1,25 -0,85 -0,45 -1,20 -0,75 -0,40 -1,20 -0,70 -0,40
10 -1,50 -1,20 - -1,65 -1,30 - -1,40 -1,00 -0,60 -1,35 -0,90 -0,50 -1,30 -0,80 -0,45 -1,30 -0,70 -0,40
20 -1,65 -1,40 - -1,80 -1,50 - -1,50 -1,15 -0,70 -1,45 -0,95 -0,55 -1,35 -0,85 -0,50 -1,35 -0,75 -0,40
≥ 50 -1,75 -1,50 - -1,90 -1,70 - -1,60 -1,35 -0,85 -1,50 -1,00 -0,60 -1,40 -0,90 -0,50 -1,40 -0,75 -0,40

Table 4 - External pressure coefficients cpe,10 for vertical walls of rectangular buildings in zones D, E
h/b D E for d/b
≤ 0,2 0,7 1,0 2,0 5,0 ≥ 10
≤ 0,5 0,8 -0,25 -0,35 -0,30 -0,15 -0,15 -0,15
2 0,8 -0,35 -0,45 -0,35 -0,20 -0,15 -0,15
5 0,8 -0,50 -0,75 -0,55 -0,30 -0,15 -0,15
10 0,8 -0,75 -1,10 -0,85 -0,50 -0,20 -0,15
20 0,8 -1,00 -1,35 -1,10 -0,65 -0,20 -0,15
≥ 50 0,8 -1,20 -1,60 -1,30 -0,85 -0,20 -0,15

cpe,1 = 1,25 • cpe,10

Clause 7.2.3 Flat roofs, paragraph (4)

Simplified calculation of the coefficients is shown in table 8.
Table 8 - Simplified external pressure coefficients cpe,10 for flat roofs
Zone F G H I
cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1
-1,3 -2,5 -1,3 -2,0 -0,7 -1,2 -0,7 -1,2
0,2 0,2 0,2 0,2

Clause 7.2.4 Monopitch roofs, paragraph (3)

Different table with external pressure coefficients is used.
Table 9 - External pressure coefficients for monopitch roofs
Pitch angle α Zone
F G H I
cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1
5 ° -1,8 -2,6 -1,8 -2,0 -0,8 -1,2 -0,8 -1,2
+0,0 +0,0 +0,0 +0,0
15 ° -1,9 -2,9 -1,9 -2,5 -0,9 -1,2 -0,9 -1,2
+0,2 +0,2 +0,2 +0,2
30 ° -1,5 -2,9 -1,5 -2,0 -1,0 -1,3 -1,0 -1,3
+0,7 +0,7 +0,4 +0,4
45 ° -1,4 -2,4 -1,4 -2,0 -1,0 -1,2 -1,0 -1,2
+0,7 +0,7 +0,2 +0,6 +0,2 +0,6
60 ° -1,2 -2,0 -1,2 -2,0 -1,0 -1,3 -1,0 -1,3
+0,7 +0,7 +0,7 +0,7
75 ° -1,2 -2,6 -1,2 -2,0 -1,0 -1,0 -1,0 -1,0
+0,8 +0,8 +0,8 +0,8

Clause 7.2.5 Duopitch roofs, paragraph (3)

Different table with external pressure coefficients is used.
Table 10 - External pressure coefficients for duopitch roofs
Pitch angle α Zone
F G H I J
cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1
-45 ° -1,2 -2,0 -1,2 -2,0 -1,0 -1,3 -1,0 -1,3 -1,2 -1,5
-30 ° -1,2 -2,1 -1,2 -2,0 -1,0 -1,3 -1,0 -1,3 -1,2 -1,4
-15 ° -1,3 -2,8 -1,3 -2,0 -0,9 -1,2 -0,9 -1,2 -1,3 -1,4
-5 ° -1,2 -2,5 -1,2 -2,0 -0,8 -1,2 -0,8 -1,2 -1,2 -0,6
+0,2 +0,0 +0,2 +0,0 +0,2 +0,0 +0,2 +0,0 +0,2
5 ° -1,2 -2,5 -1,2 -2,0 -0,7 -1,2 -0,7 -1,2 -1,2 -0,6
+0,0 +0,0 +0,0 +0,0 +0,0 +0,2
15 ° -1,0 -2,0 -1,0 -2,0 -0,6 -1,2 -0,6 -1,2 -1,0 -1,5
+0,2 +0,2 +0,2 +0,2 +0,2 +0,0
30 ° -1,4 -1,5 -1,4 -1,5 -0,8 -1,2 -0,8 -1,2 -1,4 -0,5
+0,7 +0,7 +0,4 +0,4 +0,7 +0,0
45 ° -1,3 -1,5 -1,3 -2,0 -0,9 -1,2 -0,9 -1,2 -1,3 -0,3
+0,7 +0,7 +0,6 +0,6 +0,7 +0,0
60 ° -1,2 -1,5 -1,2 -2,0 -0,8 -1,0 -0,8 -1,0 -1,2 -0,0
+0,7 +0,7 +0,7 +0,7 +0,7 +0,0
75 ° -1,2 -1,5 -1,2 -2,0 -0,8 -1,0 -0,8 -1,0 -1,2 -0,0
+0,8 +0,8 +0,8 +0,8 +0,8 +0,0

Clause 7.2.6 Hipped roofs, paragraph (3)

Different table with external pressure coefficients is used.
Table 10 - External pressure coefficients for hipped roofs
Pitch angle α Zone
F G H I J K L M N
cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1
5 ° -1,2 -2,5 -1,2 -2,0 -0,6 -1,2 -0,6 -1,2 -1,2 -2,0 -1,2 -2,0 -1,2 -2,0 -0,6 -1,2 -0,6 -1,2
+0,0 - +0,0 - +0,0 - +0,0
15 ° -1,4 -2,0 -1,4 -1,5 -0,6 -1,2 -0,6 -1,2 -1,4 -2,0 -1,4 -2,0 -1,4 -2,0 -0,6 -1,2 -0,6 -1,2
+0,2 - +0,2 - +0,2 - +0,2
30 ° -1,4 -1,5 -1,4 -1,5 -0,8 -1,2 -0,8 -1,2 -1,4 -2,0 -1,4 -2,0 -1,4 -2,0 -0,8 -1,2 -0,8 -1,2
+0,7 +0,5 +0,7 +0,4 +0,7 - +0,7 - +0,7 - +0,4
45 ° -1,3 -0,0 -1,3 -0,0 -0,8 -1,2 -0,8 -1,2 -1,3 -2,0 -1,3 -2,0 -1,3 -2,0 -0,8 -1,2 -0,8 -1,2
+0,7 +0,6 +0,7 - +0,7 - +0,7 - +0,6
60 ° -1,2 - -1,2 - -0,4 -1,2 -2,0 -1,2 -2,0 -1,2 -2,0 -0,4
+0,7 - +0,7 - +0,7 - +0,7
75 ° -1,2 - -1,2 - -0,4 -1,2 -2,0 -1,2 -2,0 -1,2 -2,0 -0,4
+0,8 - +0,8 - +0,8 - +0,8

Clause 7.2.8 Vaulted roofs and domes, paragraph (1)

The recommended procedure for determination of cpe,10 given in Standard shall be used.
cpe,1 = 1,25 • cpe,10
Roofs with f/d ≤ 0,05 should be considered as flat roofs

Clause 7.3 Canopy roofs, paragraph (6)

The recommended distance given in Standard shall be used.

Clause 7.4.1 Pressure coefficients for free-standing walls and parapets, paragraph (1)

The recommended values given in Standard should be used.

Clause 7.4.3 The value of the horizontal eccentricity, paragraph (2)

The recommended value of the horizontal eccentricity e given in Standard should be used.